Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
ROBRAC ; 27(83): 247-251, out./dez. 2018. ilus
Article in Portuguese | LILACS | ID: biblio-997256

ABSTRACT

As lesões cervicais não cariosas (LCNC) caracterizam-se pela perda irreversível e gradual de tecido mineralizado junto da junção amelo-cementária, sem qualquer envolvimento bacteriano e é um dos fatores relacionados à hipersensibilidade dentinária (HD), caracterizado por uma dor aguda, provocada e de curta duração. Paciente L.C.M, sexo feminino, 38 anos de idade, compareceu à Clínica Odontológica da Faculdade Patos de Minas (FPM), relatando sensibilidade nos dentes 44 e 45. Após assinado o Termo de consentimento livre e esclarecido (TCLE), a paciente realizou tomadas radiográficas e foi submetida a anamnese e exame clínico, no qual, foi observada a presença de LCNC e diagnosticada como multifatorial. O ajuste oclusal foi realizado com pontas diamantadas e borrachas abrasivas removendo contatos prematuros. A restauração direta em resina composta foi indicada para a obliteração mecânica/física dos túbulos dentinários, como opção de tratamento. Foi realizado condicionamento ácido do esmalte, por 30seg e da dentina por 15seg, com ácido fosfórico 37% (Condac, FGM), lavado com água pelo mesmo tempo, seguido de controle de umidade e duas camadas de adesivo convencional (Ambar, FGM), fotoativando apenas a segunda camada por 20seg com LED (Kavo 1100 mW/cm²). A LCNC foi restaurada com resina composta convencional (A3E, Llis, FGM), com dois incrementos de aproximadamente 2mm cada, seguidas de acabamento e polimento. A hipersensibilidade foi cessada imediatamente logo após o ajuste oclusal e tratamento restaurador, ressaltando a importância do diagnóstico e do exame clínico. A remoção dos contatos prematuros e a restauração com resina composta foram essenciais para o sucesso deste tratamento, visto que a origem da perda mineral foi cessada concomitante com o alívio da dor.


The non-carious cervical lesions (NCCI) are characterized by the irreversible and gradual loss of mineralized tissue combined to the amelo-cementary junction, without any bacteria participation and is one of the factors related to dentin hypersensitivity (HD), classified by an acute pain, incited and in short term. Patient L.C.M, woman, 38 years old, attended to the Dental Clinic of Faculty Patos de Minas (FPM), reporting sensitivity on teeth 44 and 45. After signed the agreement form, the patient was submitted to an anamnesis, clinical exam and x-ray, in which, it was detected the presence of NCCL, diagnosed by multifactorial. Occlusal adjustment was performed with diamond and rubber tips removing the early contact area. The resin-composite restoration was recommended as a treatment option to physic and mechanically obliterate the dentin tubules. Enamel was etched for 30 sec and dentin for 15 sec with 37% phosphoric acid (Condac, FGM) and washed with water for 30 sec. Two layers of a dentin adhesive (Ambar, FGM) was applied and light cured for 20 sec with a LED light curing unit (Kavo 1100 mW / cm²). The NCCL was restored with a resin-composite (A3E, Llis, FGM), with two increments of approximately 2mm each, followed by a finishing and polishing protocol. The hypersensitivity was interrupted immediately after occlusal adjustment and restorative treatment, emphasizing the importance of diagnosis and clinical exam. Removal of premature contacts and restoration with composite resin were essential for the success of this treatment, since the origin of the mineral loss was controlled concomitantly with pain relief.

2.
Braz. dent. j ; 26(4): 398-403, July-Aug. 2015. tab, ilus
Article in English | LILACS | ID: lil-756384

ABSTRACT

Failures may occur in the connections of dental implants, especially in external hexagon (EH). Due to the deformations in this portion of implants, this study aimed to evaluate the levels of deformation of EH connections subjected to internal toque. Two types of implants were used: N group and S group. Torques of 0, 32, 45, 60 and 80 Ncm were applied to the N group, and torques of 0, 30, 40, 60 and infinite Ncm were applied to the S group implants. The internal distance (ID), internal area (IA) and external area (EA) of the EH were obtained from digital pictures, which were analyzed by a specific software. Statistical analysis was performed by the Scott-Knott test. The results showed that the higher the torque applied, the greater were the changes in the evaluated dimensions in both groups. In the S group, torque levels equal or greater than 40 Ncm and 30 Ncm caused greater deformation of EA and IA respectively, while in the N group, torque levels equal or greater than 60 Ncm and 32 Ncm caused greater deformation of EA and IA respectively. Levels of deformation were greater in the S group as compared with the N group. These findings suggest that the IA, EA and ID of the EH may be affected by different internal torque levels.

.

Falhas podem ocorrer em conexões de implantes dentários, em especial em hexágonos externos (EH). Devido à ocorrência de deformação nesta porção dos implantes, este estudo objetivou avaliar os níveis de deformação de conexões EH submetidas ao torque interno. Dois tipos de implantes foram utilizados: grupo N e grupo S. Foram aplicados torques de 0, 32, 45, 60 e 80 Ncm nos implantes do grupo N e torques de 0, 30, 40, 60 Ncm e infinito nos implantes do grupo S. Medidas referentes à distância interna (ID), área interna (AI) e área externa (AE) foram obtidas por meio de fotos digitais analisadas em software. A análise estatística foi feita pelo teste de Scott-Knott. Os resultados demonstraram que quanto maior o torque aplicado, maior a alteração de todas as dimensões avaliadas em ambos os grupos. No grupo S, torques iguais ou superiores a 40 Ncm e 30 Ncm causaram maior deformação na AE e AI respectivamente, enquanto no grupo N, torques iguais ou superiores a 60 Ncm e 32 Ncm causaram maior deformação na AE e AI respectivamente. Os níveis de deformação foram maiores no grupo S em comparação ao grupo N. Nossos resultados indicam que a AI, a AE e a DI do EH podem ser influenciadas pelos diferentes torques internos.

.


Subject(s)
Humans , Dental Implants , Torque
3.
Braz. dent. j ; 24(4): 340-343, July-Aug/2013. tab, graf
Article in English | LILACS | ID: lil-689832

ABSTRACT

The cure time of endodontic sealers may influence the bond strength of fiber posts to root dentin. Forty teeth were selected and endodontically filled using calcium hydroxide cement and then divided into 2 groups according to the time elapsed between endodontic filling and post luting (n = 20): Immediately - glass fiber post luting immediately after endodontic filling; and Delayed - post luting performed 7 days after endodontic filling. The roots were also subdivided according to resin cement used for post luting (RelyX ARC and RelyX Unicem). The specimens were stored at 37°C for 24 h and sectioned in six 1-mm-thick slices from cervical, middle and apical thirds. The slice specimens were submitted to a push-out test at a crosshead speed of 0.5 mm/min, and the bond strength values obtained (MPa) were submitted to two-way ANOVA in a split-plot arrangement and Tukey's test (α=0.05). For both RelyX ARC and Unicem, the bond strength was significantly higher when the posts were cemented 7 days after the endodontic treatment. RelyX Unicem showed significantly higher bond strength values than RelyX ARC for both cementation periods. It was concluded that post luting should be made after the complete setting of the root canal sealer. Self-adhesive resin cement should be preferred for fiber post luting.


O tempo de presa de cimentos endodônticos pode afetar a resistência de união de pinos de fibra de vidro à dentina radicular. Quarenta dentes foram selecionados e tratados endodonticamente com cimento à base de hidróxido de cálcio. Em seguida, os mesmos foram divididos em dois grupos de acordo com o tempo decorrido entre o tratamento endodôntico e a cimentação definitiva (n=20): Imediato - pinos de fibra de vidro cimentados após o tratamento endodôntico; e Mediato - cimentação do pino realizada 7 dias após o tratamento endodôntico. As raízes foram subdivididas de acordo com o cimento resinoso (RelyX ARC e RelyX Unicem). As amostras foram armazenadas a 37 °C durante 24 h e seccionadas em seis fatias de 1 mm de espessura relacionadas com terços cervical, médio e apical. Os espécimes foram submetidos a teste de push-out a uma velocidade de 0,5 mm/min e os valores de resistência de união obtidos (MPa) foram submetidos à análise de variância em esquema de parcelas subdivididas e teste de Tukey (α=0,05). Para os cimentos RelyX ARC e Unicem, a resistência de união foi maior quando os pinos foram cimentados 7 dias após o tratamento endodôntico. RelyX Unicem apresentou valores de resistência de união superiores ao RelyX ARC para os períodos de cimentação. Concluiu-se que a cimentação do pino de fibra de vidro deve ser feita após o completo tempo de presa do cimento endodôntico. Cimentos resinosos auto-adesivos devem ser preferidos para cimentação de pinos de fibra.


Subject(s)
Humans , Dental Bonding , Dentin/chemistry , Tooth Root/chemistry , Root Canal Filling Materials , Time Factors
4.
Braz. oral res ; 27(4): 305-310, Jul-Aug/2013. tab, graf
Article in English | LILACS | ID: lil-679219

ABSTRACT

The aim of this study was to evaluate the effect of parallel and tapered threaded post placement on the strain and stress distribution of endodontically treated teeth. Fifteen bovine incisors were sectioned 15 mm from their apices, endodontically treated, and divided into three groups (n = 5) according to three different threaded posts: parallel threaded post (Radix-Anker, RA); tapered threaded post (Euro-Post, EP) and tapered threaded post (Reforpost II, RII). A strain-gauge was fixed on the proximal surface perpendicular to the long root axis, 2 mm from the cervical limit. Strain generated during post placement was recorded and compared using one-way ANOVA and Tukey's test (α= .05). A scanning electron microscope was used to examine the longitudinal root sections. Stress was evaluated for each group in a two-dimensional finite element analysis. The models were meshed with tetrahedron elements and loaded with 2 N at an angle of 135° to the lingual face. The equivalent Von Mises stress was calculated. The one-way ANOVA showed significant difference among the groups. The RA group (150.0 ± 12.2 A) produced higher external strain than the RII (80.0 ± 12.2 B) and the EP (70.0 ± 6.1 B) groups. The inner strain was approximately five times greater than the external dentin strain. High stress concentrations in each thread of the posts were observed. Scanning electron micrographs showed cracks that started in the threads of the posts. The threaded post placement induced root strain mainly on the parallel side post. Root strain and stress concentration on the post threads tended to create cracks in the inner root canal dentin.


Subject(s)
Animals , Cattle , Dental Stress Analysis/methods , Post and Core Technique , Root Canal Therapy/methods , Tooth, Nonvital/therapy , Biomechanical Phenomena , Finite Element Analysis , Materials Testing , Microscopy, Electron, Scanning , Stress, Mechanical , Surface Properties
5.
Braz. dent. j ; 21(2): 130-136, 2010. tab, ilus
Article in English | LILACS | ID: lil-551933

ABSTRACT

The aim of this study was to evaluate the influence of different periodontal therapies on the integrity of indirect restorations by scanning electron microscopy (SEM). Sixty single-rooted bovine teeth were selected and randomly assigned to 12 groups. Inlay cavities were prepared in the cervical region on the center of the cementoenamel junction, and were restored with laboratory processed resin and luted with a resin cement. Twelve periodontal therapies were used (n= 5): C: control (no treatment); MS: manual scaling with Gracey curettes; US: ultrasonic scaling; PP: prophylaxis with prophylactic paste; PS: prophylaxis with pumice-stone; SBJ: sodium bicarbonate jet; MS/PP; MS/PS; MS/SBJ; US/PP; US/PS; US/SBJ. The specimens were prepared and analyzed by SEM. SEM micrographs at ×100 to ×1000 magnification were obtained from the surface of the laboratory resin and the interface of the indirect restorations. The images were evaluated by 3 skillful, calibrated, blinded observers as to the presence of grooves, microcavities and fracture of margins. The results showed that PS produced groves on restoration surface. MS and US produced groves and marginal fractures on the restorations. SBJ resulted in resin cement degradation. These results suggest that except for PS, all procedures had deleterious effects on the marginal integrity of indirect restorations.


O objetivo desse estudo foi avaliar a influência de diferentes terapias periodontais na integridade de restaurações indiretas por meio de microscopia eletrônica de varredura (MEV). Sessenta raízes bovinas foram selecionadas e aleatoriamente divididas em 12 grupos. Preparos cavitários inlay foram realizados na região cervical central da junção cemento-esmalte e restaurados com resina laboratorial cimentado com cimento resinoso. Doze terapias periodontais foram usadas (n=5): C-sem tratamento (controle); MS-raspagem manual com cureta Gracey; US-raspagem com ultra-som; PP- profilaxia com pasta profilática; PS-profilaxia com pedra pomes; SBJ-jato de bicarbonato; MS/PP; MS/PS; MS/SBJ; US/PP; US/PS; US/SBJ. As amostras foram preparados e submetidas a MEV. Imagens, de ×100 a ×1000, da superfície da resina laboratorial e da interface das restaurações indiretas foram obtidas. As imagens foram avaliadas em procedimento cego por 3 observadores habilitados previamente calibrados seguindo os seguintes critérios: ranhuras, microcavidades e fratura de margem. Os resultados mostraram que a profilaxia com pedra pomes promoveu ranhuras na superfície das restaurações. Raspagem manual e ultrasônica promoveram ranhuras e fratura de margem das restaurações. Jato de bicarbonato resultou em degradação de cimento resinoso. Os resultados sugeriram que, exceto a profilaxia com pasta profilática, todos os procedimentos resultaram em efeitos deletérios na integridade da margem das restaurações indiretas.


Subject(s)
Animals , Cattle , Dental Marginal Adaptation , Dental Scaling , Inlays , Resin Cements/chemistry , Tooth Cervix/ultrastructure , Dental Restoration Failure , Dental Restoration, Permanent/methods , Observer Variation , Random Allocation , Single-Blind Method , Stress, Mechanical , Surface Properties , Tooth Cervix/drug effects
6.
J. appl. oral sci ; 15(2): 94-98, Mar.-Apr. 2007. ilus, tab
Article in English | LILACS | ID: lil-452763

ABSTRACT

The aim of this study was to evaluate the influence of a low-viscosity bonding resin applied over a self-etching adhesive system on the microtensile bond strength (µTBS) of indirect restorations. Comparisons were made using One Up Bond F (OB) self-etching adhesive system, Single Bond (SB) one-bottle adhesive system and Scotchbond Multi Purpose Plus (SMP) bonding component. Thirty bovine incisors were extracted and decoronated at the cementoenamel junction. The labial surfaces were ground so that superficial dentin and deep dentin were exposed. The specimens were randomized to three groups (n=10): G1- OB; G2- OB + SMP; G3- SB. In G2, a layer of the SMP bonding was applied over the OB adhesive system. Indirect composite restorations were bonded using dual-cure cement under 500 g load for 5 min. The specimens were serially sectioned with a bonding area of ± 1.0 mm² in 3 regions: enamel (E), superficial dentin (SD) and deep dentin (DD). The sticks were fixed with cyanoacrylate adhesive and submitted to µTBS test at a crosshead speed of 0.5 mm/min in a mechanical testing machine (EMIC DL 2000). The fractured specimens were examined under scanning electron microscopy to determine the failure mode. Data were analyzed by one-way ANOVA followed by Tukey's test (p<0.05). µTBS means (in MPa) were: G1/E: 15.5 ± 3.5b; G1/SD: 22.7 ± 7.6a; G1/DD: 19.4 ± 9.4a; G2/E: 15.9 ± 5.8b; G2/SD: 19.9 ± 6.9a; G2/DD: 15.3 ± 4.9a; G3/E: 23.2 ± 7.3a; G3/SD: 20.4 ± 8.2a; G3/DD: 19.1 ± 8.7a. The results showed that the use of a low viscosity bonding resin did not affect the µTBS means when associated with a self-etching adhesive system. The self-etching adhesive system was significantly more efficient in dentin than in enamel, while the one-bottle system was significantly more efficient in enamel when compared to the self-etching adhesive system.

7.
Clín. int. j. braz. dent ; 2(3): 280-286, jul.-set. 2006. ilus
Article in Portuguese | LILACS, BBO | ID: lil-526013

ABSTRACT

Lesões cervicais não cariosas são cada vez mais prevalentes e apresentam diversos fatores etiológicos. A origem das lesões em forma de cunha tem sido relacionada à presença de interferências oclusais. Neste estudo, aborda-se uma revisão da literatura pertinente e análise crítica dos fatores etiológicos de lesões cervicais não cariosas, com destaque para o papel das forças oclusais para-funcionais como fator predisponente para gerar lesão de abfração, sendo sua evolução e seu agravamento modulados por fatores coadjuvantes, como escovação excessiva, ação química e desmineralização cervical. Imagens obtidas por método de elementos finitos e fotoelasticidade enfatizam a hipótese da origem mecânica dessas lesões.


Subject(s)
Dental Occlusion , Tooth Erosion , Tooth Injuries
8.
Ciênc. odontol. bras ; 9(2): 67-74, abr.-jun. 2006. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-457307

ABSTRACT

Este trabalho avaliou a resistência adesiva (µTBS) na fixação de restaurações indiretas por meio de cimento resinoso e adesivo auto-condicionante sob influência de diferentes tratamentos prévios de esmalte e dentina. Trinta incisivos bovinos foram extraídos e tiveram suas raízes cortadas na junção cemento-esmalte. A superfície vestibular dos dentes foi lixada até exposição de dentina superficial, padronizando a formação de smear layer. As amostras foram divididas aleatoriamente em três grupos (n=10): G1: aplicação do adesivo auto-condicionante One up Bond F (OB), seguindo as instruções do fabricante; G2:condicionamento com ácido fosfórico à 37% em esmalte e dentina seguindo aplicação de (OB); G3: jateamento com óxido de alumínio 50µm em esmalte e dentina previamente à aplicação de (OB). Restaurações indiretas com resina composta foram fixadas usando cimento resinoso dual e as amostras foram cortadas com área adesiva de aproximadamente 1,0 mm² em três regiões: esmalte (E), dentina periférica (DP) e dentina central (DC). Foram submetidas a ensaio de microtração em máquina de ensaio mecânico em velocidade de 0,5mm/min. Após fratura, as amostras foram analisadas em Microscopia Eletrônica de Varredura (MEV) para avaliação do padrão de fratura. Os valores de (µTBS) foram expressos em MPa e os dados foram analisados em ANOVA seguido por teste Tukey (p<0,05). Os resultados foram: E/G2: 30,4±11,9a; E/G3: 16,0±8,9b; E/G1: 15,8±5,8b; DP/G1: 24,2±12,1a; DP/G3: 15,2±7,1b; DP/G2: 15,0±9,8b; DC/G1: 17,3±10,4a; DC/G3: 11,6±3,5b; DC/G2: 11,4±5,2b. O jateamento não aumentos os valores de (µTBS). O prévio condicionamento ácido aumentou a resistência adesiva em esmalte e diminuiu em dentina.


Subject(s)
Animals , Cattle , Air Abrasion, Dental , Dental Restoration, Permanent , Dentin-Bonding Agents , Phosphoric Acids , Tensile Strength , Tooth Preparation , Analysis of Variance , Microscopy, Electron, Scanning , Smear Layer
SELECTION OF CITATIONS
SEARCH DETAIL